Ferritin Assay Rapid And Elisa And Chemiluminanace

Rapid Yeast and Mould - PK50

FSA1022 PK50
EUR 128.25

Ferritin Elisa Laboratories manufactures the ferritin assay rapid and elisa and chemiluminanace reagents distributed by Genprice. The Ferritin Assay Rapid And Elisa And Chemiluminanace reagent is RUO (Research Use Only) to test human serum or cell culture lab samples. To purchase these products, for the MSDS, Data Sheet, protocol, storage conditions/temperature or for the concentration, please contact ferritin elisa. Other Ferritin products are available in stock. Specificity: Ferritin Category: Assay Group: Rapid And

HDL and LDL/VLDL Assay Kit

100 assays
EUR 898

Super PlusTMHigh Sensitive and Rapid Immunohistochemical Kit (pH9.0)

10mL
EUR 325

Super PlusTMHigh Sensitive and Rapid Immunohistochemical Kit (pH9.0)

3mL
EUR 125

Super PlusTMHigh Sensitive and Rapid Immunohistochemical Kit (pH9.0)

each Ask for price

Super PlusTMHigh Sensitive and Rapid Immunohistochemical Kit (pH6.0)

10mL
EUR 325

Super PlusTMHigh Sensitive and Rapid Immunohistochemical Kit (pH6.0)

3mL
EUR 125

Super PlusTMHigh Sensitive and Rapid Immunohistochemical Kit (pH6.0)

each Ask for price

Rapid And information

NSD3 Chemiluminescent Assay Kit

79358 384 rxns.
EUR 1950
Description: The NSD3 Chemiluminescent Assay Kit is designed to measure NSD3 activity for screening and profiling applications. The key to the NSD3 Chemiluminescent Activity Assay Kit is a highly specific antibody that recognizes methylated residue of Histone H3. With this kit, only three simple steps are required for methyltransferase detection. First, Sadenosylmethionine is incubated with a sample containing assay buffer and methyltransferase enzyme. Next, primary antibody is added. Finally, the plate is treated with an HRP-labeled secondary antibody followed by addition of the HRP substrate to produce chemiluminescence that can then be measured using a chemiluminescence reader.

NSD2 Chemiluminescent Assay Kit

79359 384 rxns.
EUR 1100
Description: The NSD2 Chemiluminescent Assay Kit is designed to measure NSD2 activity for screening and profiling applications. The key to the NSD2 Chemiluminescent Activity Assay Kit is a highly specific antibody that recognizes methylated residue of Histone H3. With this kit, only three simple steps are required for methyltransferase detection. First, Sadenosylmethionine is incubated with a sample containing assay buffer and methyltransferase enzyme. Next, primary antibody is added. Finally, the plate is treated with an HRP-labeled secondary antibody followed by addition of the HRP substrate to produce chemiluminescence that can then be measured using a chemiluminescence reader.

P300 Chemiluminescent Assay Kit

79705 96 rxns.
EUR 465
Description: The p300 Chemiluminescent Assay Kit is an enzyme-linked immunosorbent assay (ELISA) designed to screen for inhibitors of p300 or to measure histone acetyltransferase (HAT) activity for screening and profiling applications. Histone acetyltransferase p300 (also known as KAT3B) is involved in various cellular events, and its dysfunction is linked to a number of human diseases including Parkinson's, Huntington's, and Alzheimer's diseases. The P300 Chemiluminescent Assay Kit is based on the p300 enzyme transferring an acetyl group from an acetyl donor (acetyl CoA) to a histone substrate. The acetylated histone is recognized by a highly specific primary antibody, followed by an HRP-labeled secondary antibody. The chemiluminescence produced by HRP can be measured using a chemiluminescence reader._x000D_

ATP Chemiluminescence Assay Kit

E-BC-F002-48T 48T
EUR 3
Description: Quantitative

ATP Chemiluminescence Assay Kit

E-BC-F002-96T 96T
EUR 450
Description: Quantitative

ATP Chemiluminescence Assay Kit

E-BC-F002-each each Ask for price
Description: Quantitative

LSD1 Chemiluminescent Assay Kit

GWB-PS5F05 96reactions Ask for price

ATP Chemiluminescence Assay Kit

MBS2567661-48Test 48Test
EUR 355

ATP Chemiluminescence Assay Kit

MBS2567661-48Tests 48Tests
EUR 355

ATP Chemiluminescence Assay Kit

MBS2567661-5x96Tests 5x96Tests
EUR 2175

ATP Chemiluminescence Assay Kit

MBS2567661-96Test 96Test
EUR 475

ATP Chemiluminescence Assay Kit

MBS2567661-96Tests 96Tests
EUR 475

PRMT5 Chemiluminescent Assay Kit

52002L 96 rxns.
EUR 865
Description: The PRMT5 Direct Activity Chemiluminescent Assay Kit is designed to measure PRMT5_x000D_ activity for screening and profiling applications. The key to the PRMT5_x000D_ Chemiluminescent Assay Kit is a highly specific antibody that recognizes methylated R3_x000D_ residue of Histone H4. With this kit, only three simple steps on a microtiter plate are_x000D_ required for methyltransferase detection. First, S-adenosylmethionine is incubated with a_x000D_ sample containing assay buffer and methyltransferase enzyme for one hour. Next,_x000D_ primary antibody is added. Finally, the plate is treated with an HRP-labeled secondary_x000D_ antibody followed by addition of the HRP substrate to produce chemiluminescence that_x000D_ can then be measured using a chemiluminescence reader.

PRMT1 Chemiluminescent Assay Kit

52004L 96 rxns.
EUR 790
Description: The PRMT1 Direct Activity Chemiluminescent Assay kit is designed to measure PRMT1 activity for screening and profiling applications. The key to the PRMT1_x000D_Chemiluminescent Assay Kit is a highly specific antibody that recognizes methylated R3_x000D_residue of Histone H4. With this kit, only three simple steps are required for_x000D_methyltransferase detection. First, S-adenosylmethionine is incubated with a sample_x000D_containing assay buffer and methyltransferase enzyme. Next, primary antibody is added._x000D_Finally, the strip plates are treated with an HRP-labeled secondary antibody followed by_x000D_addition of the HRP substrate to produce chemiluminescence that can then be measured_x000D_using a chemiluminescence reader.

PRMT3 Chemiluminescent Assay Kit

52005L 96 rxns.
EUR 750
Description: The PRMT3 Direct Activity Chemiluminescent Assay kit is designed to measure PRMT3_x000D_activity for screening and profiling applications. The key to the PRMT3 Direct Activity Assay Kit is a highly_x000D_specific antibody that recognizes methylated substrate. With this kit, only three simple_x000D_steps on a microtiter plate are required for methyltransferase detection. First,_x000D_Sadenosylmethionine is incubated with a sample containing assay buffer and_x000D_methyltransferase enzyme for one hour. Next, primary antibody is added. Finally, the_x000D_plate is treated with an HRP-labeled secondary antibody followed by addition of the HRP_x000D_substrate to produce chemiluminescence that can then be measured using a_x000D_chemiluminescence reader.

PRMT4 Chemiluminescent Assay Kit

52041L 96 rxns.
EUR 750
Description: The PRMT4 Direct Activity Chemiluminescent Assay kit is designed to measure PRMT4/CARM1 activity activity for screening and profiling applications. The key to the PRMT4_x000D_Chemiluminescent Assay Kit is a highly specific antibody that recognizes methylated_x000D_PRMT4 substrate. With this kit, only three simple steps on a microtiter plate are required_x000D_for methyltransferase detection. First, S-adenosylmethionine is incubated with a sample_x000D_containing assay buffer and methyltransferase enzyme. Next, primary antibody is added._x000D_Finally, the strip plates are treated with an HRP-labeled secondary antibody followed by_x000D_addition of an HRP substrate to produce chemiluminescence that can then be measured_x000D_using a chemiluminescence reader.

DNMT1 Chemiluminescent Assay Kit

52050L 96 rxns.
EUR 865
Description: The DNMT1 Assay Kit is designed to measure DNMT1 activity for screening and profiling applications. The key to the DNM1 Assay Kit is a highly specific antibody that recognizes 5-methylcytosine on the substrate. With this kit, only three simple steps on a microtiter plate are required for DNMT1 detection. First, S-adenosylmethionine is incubated with a sample containing assay buffer and DNMT1 for one hour. Next, primary antibody is added. Finally, the plate is treated with an HRP-labeled secondary antibody followed by addition of the HRP substrate to produce chemiluminescence that can then be measured using a chemiluminescence reader.